NEW Introducing TimeShift - AI-powered shift planning

Facilities & Property checklist

Preventive Maintenance Inspection Checklist

Verify preventive-maintenance execution across work orders, mechanical and electrical assets, HVAC, plumbing, life-safety support equipment, building fabric, safe maintenance practices, overdue PM, recurring defects, corrective work, reinspection, and final sign-off.

✓ Printable PDF✓ 10 PM inspection sections✓ 60 practical checks
Preventive Maintenance InspectionProperty 018 | Plant Room 02 | Monthly review
6 of 10

Critical check | PM completion and asset condition

Does the completed PM record match the actual asset condition, with required safeguards restored and all discovered defects converted into accountable corrective work?

Select an answer to preview the workflow.

About this checklist

What a preventive maintenance inspection checklist should help you verify

Verify that scheduled preventive work was completed at the required frequency, the recorded evidence is credible, actual asset condition supports the closure, and defects discovered during PM are routed into corrective maintenance rather than disappearing inside completed work orders.

When

PM quality inspections, monthly maintenance reviews, contractor verification, and repeat-failure follow-up

Use it to sample completed PM work orders, inspect critical assets after planned maintenance, verify contractor service, investigate repeat failures, review overdue work, or prepare for maintenance-performance reviews.

Who

Facilities, engineering, maintenance, property management, EHS, operations, and specialist contractors

Maintenance supervisors, facility managers, engineers, property teams, EHS, operations leads, technicians, and specialist service contractors can provide records, field evidence, and corrective-action ownership.

Outcome

Verified PM completion with better asset reliability and clearer corrective-work ownership

Create one evidence trail for schedule adherence, technician work, readings, actual condition, safeguards, defects, corrective work, backlog, contractor performance, reinspection, and final approval.

Complete preventive maintenance inspection

60 checks across PM schedules and work orders, mechanical equipment, electrical assets, HVAC, plumbing, life-safety support systems, building fabric, safe maintenance practice, overdue work, recurring defects, corrective actions, reinspection, and sign-off

Ten sections, sixty checks. Adapt the checklist to your asset register, criticality model, CMMS or work-order system, manufacturer requirements, specialist maintenance programmes, safe-work procedures, service contracts, building type, and local regulatory obligations.

Section 1Inspection scope, asset list, PM schedule, criticality, ownership, and previous defects
  • Confirm the property, building, floor or zone, inspection date, maintenance period, and preventive-maintenance inspection scope are clearly identified.
  • Identify the assets, systems, rooms, equipment groups, or PM work orders included in the inspection and confirm each has a unique asset or location reference.
  • Verify the current preventive-maintenance schedule identifies required tasks, frequencies, critical assets, responsible team or contractor, and expected completion dates.
  • Review previous PM inspection findings, repeated breakdowns, overdue work orders, recurring alarms, leaks, safety defects, and unresolved maintenance actions before sampling.
  • Confirm ownership is defined across facilities, engineering, maintenance, property management, specialist contractors, EHS, and operations for inspected PM activities.
  • Record property, inspection date, asset group or zone, inspector, maintenance owner, facilities owner, contractor where applicable, and next planned review date.
Section 3Mechanical equipment, rotating assets, guards, lubrication, belts, bearings, vibration clues, and condition
  • Inspect pumps, motors, fans, gearboxes, drives, compressors, or other rotating equipment in scope for visible leakage, looseness, damage, or abnormal operating condition.
  • Confirm required guards, covers, couplings, belt guards, shaft protection, and access panels are securely reinstalled after maintenance.
  • Check lubrication points, oil levels, grease fittings, reservoirs, seals, and visible lubricant condition against the PM requirement where safely accessible.
  • Inspect belts, chains, couplings, pulleys, bearings, mounts, anti-vibration supports, and fasteners for obvious wear, damage, looseness, or misalignment.
  • Review recorded vibration, temperature, noise, pressure, flow, or condition-monitoring readings where required and confirm abnormal results triggered action.
  • Escalate oil or fluid leaks, overheating, abnormal noise, excessive vibration, missing guards, loose mounts, or other conditions requiring corrective maintenance.
Section 5HVAC, air-handling, filters, coils, belts, condensate, controls, temperatures, and ventilation condition
  • Inspect air-handling units, fan-coil units, package units, split systems, exhaust fans, cooling equipment, and other HVAC assets included in the PM sample.
  • Confirm filters were inspected or replaced at the required interval and are correctly fitted, clean enough for service, and not bypassing the filter frame.
  • Inspect visible coils, drain pans, condensate lines, traps, insulation, access panels, and surrounding areas for dirt, water, blockage, corrosion, leakage, or microbial growth clues.
  • Check belts, pulleys, fan sections, dampers, actuators, guards, vibration mounts, and accessible mechanical components for serviceable condition.
  • Review recorded temperatures, pressures, differential pressure, airflow, control setpoints, alarms, refrigerant-related observations, or other required PM readings where applicable.
  • Escalate water leakage, blocked condensate, failed fans, abnormal noise, poor airflow, repeated alarms, damaged insulation, or other HVAC defects requiring corrective work.
Section 7Fire and life-safety support assets, emergency equipment, service evidence, impairments, and PM interfaces
  • Confirm fire-alarm, emergency-lighting, fire-door, extinguisher, sprinkler, pump, generator, or other life-safety PM activities included in scope have current service evidence where applicable.
  • Check visible life-safety equipment and associated access points are unobstructed and have no obvious damage, isolation, fault, or overdue maintenance indicator.
  • Review active impairments, disabled points, isolated valves, unavailable emergency equipment, or overdue specialist service and confirm each has an owner and restoration plan.
  • Verify PM work around life-safety systems did not leave covers removed, doors wedged, panels isolated, valves closed, devices obstructed, or equipment unavailable after maintenance.
  • Confirm specialist test, maintenance, or certification reports are linked to the correct asset and unresolved deficiencies are transferred into corrective work.
  • Escalate any condition that reduces required fire or life-safety protection and apply the site's approved impairment process where required.
Section 9Safe maintenance practice, isolation, tools, housekeeping, spares, contractor controls, and return-to-service readiness
  • Confirm required isolation, lockout or tagout, permit, access-control, or other safe-maintenance process was used for sampled work where applicable.
  • Verify guards, covers, interlocks, access panels, emergency stops, barriers, and safety devices removed for maintenance were correctly restored before return to service.
  • Check tools, rags, packaging, used parts, lubricants, chemicals, temporary leads, barriers, warning signs, and maintenance waste were removed or properly controlled after work.
  • Inspect maintenance stores and critical spares used for PM for correct identification, suitable storage, shelf-life control where relevant, and availability for critical assets.
  • Confirm contractors completed required site induction, permits, service reports, defect escalation, housekeeping, and handback documentation for sampled maintenance work.
  • Escalate missing guards, incomplete isolation removal, unsafe temporary repairs, abandoned tools or materials, uncontrolled chemicals, or equipment returned to service in an unsafe condition.
Section 2PM work orders, task completion, frequencies, checklists, technician evidence, and close-out quality
  • Confirm sampled PM work orders were completed within the required frequency or approved tolerance and overdue work is clearly identified.
  • Verify each sampled work order includes the required PM task list, completion date, technician or contractor identity, asset ID, and relevant observations.
  • Check that required readings, measurements, lubrication, cleaning, adjustments, replacements, inspections, or functional checks are recorded where applicable.
  • Compare completed PM records with actual asset condition to identify work that appears missed, incomplete, inaccurately closed, or not supported by evidence.
  • Confirm defects discovered during PM are not hidden inside completed work orders and have been converted into corrective work, repair requests, or engineering review as required.
  • Review repeat extensions, deferred PM, duplicate closures, missing evidence, abnormal completion times, or repeated no-fault findings for possible maintenance-process weakness.
Section 4Electrical assets, panels, connections, batteries, lighting, controls, access, and visible maintenance condition
  • Inspect electrical rooms, panels, distribution boards, starters, control cabinets, UPS units, batteries, lighting panels, and related assets in the PM sample for visible condition and access.
  • Confirm panel covers, blanks, doors, labels, locks, guards, and enclosure hardware are secure and left correctly reassembled after maintenance.
  • Check required access and working space around electrical equipment is not blocked by storage, cleaning materials, tools, spare parts, or maintenance waste.
  • Inspect visible cables, conduits, glands, plugs, sockets, isolators, switches, emergency stops, and external connections for obvious damage, heat discoloration, looseness, or deterioration.
  • Verify battery, UPS, emergency-power, charger, or backup-system PM records include required condition checks, replacement dates, alarms, and test evidence where applicable.
  • Escalate exposed live-part risk, damaged enclosures, overheating clues, loose or damaged electrical components, unresolved alarms, or unsafe access conditions to qualified electrical personnel.
Section 6Plumbing, pumps, tanks, valves, water systems, drains, leaks, and preventive service condition
  • Inspect pumps, tanks, valves, water heaters, pressure systems, visible pipework, drainage equipment, sump systems, and plumbing assets included in the PM sample.
  • Check visible joints, seals, valves, gauges, flexible connections, drains, traps, strainers, and equipment bases for leakage, corrosion, damage, or poor condition.
  • Confirm required valve exercises, strainer cleaning, flushing, descaling, tank checks, pump checks, or other planned plumbing tasks are documented where applicable.
  • Review recorded pressures, temperatures, levels, pump status, alarms, run hours, or other maintenance readings required by the PM plan.
  • Inspect plant-room drains, condensate routes, floor drains, sump pits, and surrounding housekeeping for blockage, standing water, overflow, or repeated leakage.
  • Escalate active leaks, pressure loss, pump failure, corrosion, drainage problems, water damage, or repeated plumbing defects for corrective maintenance.
Section 8Building fabric, doors, roofs, drainage, finishes, access systems, and recurring property defects
  • Inspect sampled roofs, gutters, drains, doors, windows, sealants, ceilings, walls, floors, access systems, or other building-fabric items included in the PM plan.
  • Confirm doors, closers, locks, hinges, automatic operators, access-control components, shutters, gates, or similar maintained assets operate correctly after PM where included.
  • Check roof and external drainage PM evidence addresses debris, blocked outlets, damaged gutters, downpipes, standing water, leakage, and visible deterioration where applicable.
  • Inspect recurring leak points, sealant joints, water stains, damaged finishes, corrosion, cracked surfaces, or building-envelope clues for unresolved deterioration.
  • Verify planned periodic tasks such as roof cleaning, door adjustment, sealant inspection, drainage clearing, coating checks, or facade-access servicing are recorded where applicable.
  • Escalate structural warning signs, active water ingress, failed doors, severe deterioration, unsafe access, or defects requiring specialist assessment rather than routine PM.
Section 10Inspection result, overdue PM, corrective work, verification, repeat failures, backlog, and final sign-off
  • Classify each finding by missed PM, incomplete task, mechanical, electrical, HVAC, plumbing, life safety, building fabric, safety control, contractor, documentation, or other approved category.
  • Prioritize findings using asset criticality, safety risk, service impact, condition deterioration, repeated failure, statutory or specialist requirement, and urgency.
  • Create or link corrective work orders, specialist service, replacement, engineering review, parts procurement, contractor action, or programme changes with named owners and due dates.
  • Review overdue PM, deferred work, repeat breakdowns, recurring alarms, repeated leaks, chronic defects, and maintenance backlog for assets needing stronger intervention.
  • Verify significant corrective work through reinspection, live photos, updated readings, functional tests, completed work orders, service reports, or specialist evidence before closure.
  • Record final PM-inspection status, critical open defects, overdue maintenance, deferred work, repeat failures, next inspection date, inspector, maintenance owner, facilities owner, and management approval.

Take it with you

Download the printable PDF to sample completed PM work, compare records with actual asset condition, capture live defects, and connect corrective maintenance, specialist service, overdue work, contractor action, and reinspection to accountable owners.

Use the complete checklist during your next preventive maintenance inspection

This internal Facilities & Property template supports preventive-maintenance quality inspection. Apply current manufacturer instructions, safe-work procedures, electrical and mechanical requirements, specialist inspection or testing obligations, service contracts, building rules, and local regulatory requirements.
Download PDF Checklist

How to use it

Turn preventive maintenance inspections into a controlled verify-to-correct workflow

Select the PM sample, compare work-order evidence with actual field condition, separate incomplete maintenance from new defects, then assign corrective work and verify the asset before final closure.

01

Select assets and PM evidence

Choose critical assets, overdue or recently completed work, repeat-failure equipment, contractor jobs, and a representative sample from the current PM period.

02

Inspect actual condition

Compare work orders with mechanical, electrical, HVAC, plumbing, building, life-safety support, readings, safeguards, housekeeping, and return-to-service condition.

03

Create corrective work

Turn incomplete PM, defects, unsafe conditions, abnormal readings, repeat failures, or missing evidence into named corrective actions, specialist service, or engineering review.

04

Verify closure and improve the programme

Reinspect significant defects, confirm updated readings and functional results, review backlog and recurring failures, and feed learning into PM frequencies and task content.

Live interactive demo

See how preventive maintenance inspections work when they are run in Taqtics

Use the digital workflow to sample completed PM work, capture live asset condition, identify incomplete tasks or new defects, assign corrective maintenance, verify closure, and compare repeat failures or overdue work across properties.

Traceable PM inspection evidence

Capture property, asset, work order, PM task, completion date, technician, readings, actual condition, live photo, finding, owner, action, and reinspection history together.

Faster defect and backlog ownership

Turn incomplete PM, abnormal readings, leaks, missing guards, repeat alarms, overdue work, unsafe handback, or contractor misses into accountable corrective maintenance.

Comparable maintenance quality

Track PM completion quality, repeat defects, overdue work, contractor performance, rework, breakdown recurrence, backlog, and verified corrective closure across properties.

Taqtics
Retail Stock AuditStock Audit Checklist
0 of 6 answered

1 Select the stock-audit area

Dropdown

2 Does the sampled physical quantity match the system quantity after movement cut-off?

Critical score

3 Enter the variance percentage for the sampled item

Measurement

4 Select the evidence reviewed

Multiple choice

5 Add live stock-audit evidence

Live evidence

6 Record the variance, root cause, and required corrective action

Comments

Illustrative website demo. Responses are not stored or submitted.

Why digitize it

A clearer way to inspect preventive maintenance across every property

Taqtics connects scheduled PM inspection, live asset evidence, work-order quality, abnormal readings, corrective maintenance, overdue work, contractor performance, reinspection, recurring trends, and reporting.

Verify completed PM consistently

Capture property, asset, work order, scheduled task, completion evidence, readings, actual condition, photo, owner, due date, and inspection history together.

Standardize defect and evidence quality

Use consistent status options, critical-defect rules, photo requirements, reading checks, safe-handback criteria, repair categories, and reinspection expectations.

Route corrective maintenance immediately

Assign mechanical, electrical, HVAC, plumbing, life-safety, building, specialist, contractor, parts, or engineering action while retaining the original PM evidence.

Compare reliability across properties

Track incomplete PM, overdue work, repeat breakdowns, recurring defects, abnormal readings, contractor misses, rework, backlog, and verified closure across sites.

Frequently asked questions

Preventive maintenance inspection checklist FAQs

What should a preventive maintenance inspection checklist cover?

It should cover PM scope and schedules, work-order completion quality, technician evidence and readings, mechanical equipment, electrical assets, HVAC, plumbing, life-safety support equipment, building fabric, safe maintenance practice, contractor handback, overdue PM, recurring defects, corrective work, reinspection, backlog, and final sign-off.

How is this different from a preventive maintenance checklist?

A preventive maintenance checklist guides the maintenance programme and recurring tasks. A preventive maintenance inspection checklist independently verifies that scheduled PM was completed correctly and that actual asset condition supports the recorded closure.

What should be checked in completed PM work orders?

Check asset identification, scheduled task, completion date, technician or contractor, required readings, adjustments, lubrication, cleaning, replacements, observations, evidence, defects discovered, parts used where relevant, and whether corrective work was created for unresolved issues.

How should overdue preventive maintenance be handled?

Prioritize overdue work using asset criticality, safety and compliance impact, service consequences, condition deterioration, repeat failure, and time overdue. Record approved deferrals explicitly and escalate critical or repeatedly deferred PM.

What should happen when the inspection finds a defect after PM was marked complete?

Document the actual condition, make the asset safe where needed, create corrective maintenance or specialist work, assign an owner and due date, and reinspect before closing the inspection finding. The original PM record should remain traceable.

Does this checklist replace specialist maintenance or statutory testing?

No. It is an internal maintenance-quality inspection template. It does not replace manufacturer-required maintenance, statutory inspections, fire-system testing, electrical testing, pressure-system examinations, lift inspections, specialist certification, or authority requirements.

Digitize every stock audit

Run retail stock audits with live evidence and accountable variance control

Maintain one operational view of count completion, stock accuracy, value variance, shrink risk, open actions, approvals, and recurring inventory-control issues.

Printable PDF | Free Taqtics trial | No credit card required