NEW Introducing TimeShift - AI-powered shift planning

Facilities & Property checklist

Facility Inspection Checklist

Inspect buildings and property across exterior condition, common areas, walking surfaces, building envelope, electrical systems, fire and emergency access, HVAC and plumbing, housekeeping, storage, work orders, preventive maintenance, and final facility sign-off.

✓ Printable PDF✓ 10 facility sections✓ 60 practical checks
Facility InspectionProperty 018 | Building A | Level 02
6 of 10

Critical check | safe access and egress

Are walking routes, exits, emergency access, and critical building systems free from conditions that require immediate control?

Select an answer to preview the workflow.

About this checklist

What a facility inspection checklist should help you verify

Verify that buildings, common areas, access routes, utilities, emergency systems, service spaces, and property conditions are inspected consistently, unsafe defects are controlled, and maintenance actions are tracked through verified completion.

When

Routine facility rounds, scheduled property inspections, seasonal checks, and post-repair follow-up

Use it for weekly or monthly facility rounds, landlord or property-management checks, pre-opening reviews, seasonal inspections, after severe weather, after major repairs, after complaints, or when recurring defects need structured follow-up.

Who

Facilities, property management, engineering, maintenance, EHS, housekeeping, and contractors

Facility managers, property teams, maintenance, engineering, EHS, housekeeping, security, landlords, service contractors, and operations leaders can share inspection responsibilities.

Outcome

Safer buildings with visible defects, owners, work orders, and verification

Create one evidence trail for property condition, safe access, electrical and fire issues, utilities, leaks, housekeeping, defects, work orders, preventive maintenance, reinspection, and sign-off.

Complete facility inspection checklist

60 checks across exterior condition, common areas, walking surfaces, building envelope, electrical systems, fire and emergency access, HVAC, plumbing, service areas, housekeeping, work orders, preventive maintenance, and sign-off

Ten sections, sixty checks. Expand any section, then adapt the checklist to your property type, lease responsibilities, building and fire requirements, maintenance standards, asset criticality, accessibility obligations, local regulations, and site-specific risk controls.

Section 1Facility scope, inspection readiness, occupancy, ownership, and previous findings
  • Confirm the facility, building, property, floor, zone, inspection date, occupancy or operating status, and inspection scope are clearly identified.
  • Verify current floor plans, asset lists, emergency information, preventive-maintenance schedules, prior inspection findings, and open work orders are available where needed.
  • Confirm high-risk or restricted areas such as roofs, electrical rooms, mechanical rooms, plant rooms, loading areas, and service spaces are included or intentionally excluded with a reason.
  • Review previous facility defects, repeated leaks, trip hazards, lighting failures, electrical concerns, fire-safety issues, complaints, incidents, and overdue repairs before sampling.
  • Confirm responsible facility, engineering, maintenance, housekeeping, security, EHS, landlord, or contractor contacts are identified for follow-up.
  • Record property or facility name, inspection date, zone or floor, inspector, facility owner, maintenance contact, and planned follow-up date.
Section 3Entrances, lobbies, corridors, common areas, doors, and routine access
  • Inspect main entrances, vestibules, reception areas, lobbies, corridors, common rooms, and circulation routes for cleanliness, damage, congestion, and safe access.
  • Confirm corridors, passageways, and routine access routes are free from materials, furniture, cables, waste, temporary equipment, or other obstructions that create a hazard.
  • Check doors, frames, closers, handles, locks, panic or exit hardware where applicable, glazing, seals, and thresholds for safe operation and visible damage.
  • Verify internal lighting is adequate for the area and failed lamps, damaged fittings, flicker, dark zones, or emergency-light defects are reported.
  • Inspect mats, floor transitions, thresholds, cable covers, floor penetrations, and temporary coverings for secure installation and trip resistance.
  • Confirm access-control, visitor, key, security, or restricted-area arrangements provided by the facility are functioning as intended without obstructing required emergency egress.
Section 5Building envelope, walls, ceilings, windows, roofs, moisture, and structural condition
  • Inspect walls, partitions, columns, ceilings, soffits, visible structural elements, and finishes for cracks, impact damage, movement, loose materials, or deterioration.
  • Check windows, glazing, frames, seals, louvers, vents, skylights, and external openings for cracks, broken components, water entry, or unsafe condition.
  • Look for roof leaks, ceiling stains, dampness, condensation, active water ingress, mold-like growth, corrosion, damaged insulation, or repeated moisture evidence.
  • Confirm damaged ceiling tiles, loose panels, suspended items, fixtures, signage, or overhead components are secured or isolated where they could fall.
  • Verify visible roof, gutter, flashing, sealant, joint, facade, and waterproofing defects are linked to maintenance review rather than only cosmetic repair where water entry may continue.
  • Escalate signs of structural movement, significant cracking, unstable components, falling-material risk, or other conditions requiring qualified engineering assessment.
Section 7Fire protection, emergency exits, exit routes, alarms, extinguishers, and emergency access
  • Confirm required exit routes, exit access, exit doors, stairs, corridors, and discharge areas are unobstructed and not used for temporary storage.
  • Verify exit signs, directional signs, emergency lighting, and other egress markings provided by the facility are visible and operational.
  • Inspect fire extinguishers, hose cabinets, fire doors, alarm points, detectors, sprinkler valves, risers, hydrant or fire-service access, and other visible fire-protection assets for blocked access or obvious damage.
  • Confirm fire doors and smoke-control doors provided by the facility are not improperly propped, obstructed, damaged, or prevented from operating as intended.
  • Check emergency equipment, alarm panels, evacuation information, assembly-point information, and responder access are available and not hidden by construction, storage, displays, or temporary work.
  • Record any impairment, isolation, out-of-service fire-protection system, blocked exit route, or emergency-access issue requiring immediate escalation and interim controls.
Section 9Housekeeping, waste, storage, pests, service areas, and general property condition
  • Confirm work areas, storerooms, service rooms, utility spaces, janitorial areas, corridors, and common spaces are maintained in a clean and orderly condition.
  • Check waste, recycling, cardboard, packaging, combustible materials, discarded furniture, and maintenance debris are removed or stored in designated areas.
  • Verify storage does not block doors, exits, electrical equipment, fire equipment, valves, access panels, service routes, ventilation, or maintenance access.
  • Inspect for pest evidence such as droppings, nesting, insects, damaged packaging, entry gaps, stagnant water, or waste conditions requiring pest-control follow-up.
  • Confirm chemical, janitorial, maintenance, paint, fuel, gas-cylinder, or other service-material storage follows the site's approved segregation, labeling, access, and spill-control requirements.
  • Record odors, cleanliness complaints, graffiti, damaged furnishings, broken fixtures, loose signage, vandalism, or other property-condition issues requiring repair or service.
Section 2Exterior condition, grounds, parking, access routes, drainage, and perimeter safety
  • Inspect external walkways, paths, ramps, curbs, parking areas, loading approaches, and pedestrian routes for damage, uneven surfaces, holes, loose materials, or trip hazards.
  • Check exterior stairs, handrails, guardrails, ramps, landings, bollards, barriers, and protective structures for stability, damage, corrosion, or missing components.
  • Verify site drainage, gutters, downpipes, channels, grates, roof drains, and surface grading are not creating ponding, overflow, erosion, or uncontrolled water entry.
  • Inspect exterior walls, facades, canopies, roofs visible from safe access points, signs, awnings, fences, gates, and perimeter elements for deterioration or loose components.
  • Confirm exterior and parking-area lighting is operational where provided and dark, damaged, or failed lighting locations are recorded for action.
  • Check entrances, delivery points, emergency access, fire-lane or responder access, gates, and perimeter routes remain usable and are not blocked by stored materials, vehicles, or temporary work.
Section 4Floors, stairs, ladders, platforms, handrails, guardrails, and walking-working surfaces
  • Inspect floors and walking-working surfaces for cracks, holes, loose tiles, damaged coatings, uneven edges, protrusions, slippery conditions, or other defects.
  • Confirm spills, leaks, standing water, dust, debris, waste, and other surface contamination are controlled promptly and affected areas are protected until safe.
  • Check stairs, treads, nosings, landings, handrails, guardrails, platforms, and elevated access surfaces for secure condition and visible deterioration.
  • Verify fixed ladders, portable ladders provided for facility work, access hatches, roof access, and other access equipment are stored, maintained, and controlled according to applicable site requirements.
  • Confirm walking-working surfaces used by employees are inspected regularly and known defects are repaired or otherwise controlled before normal use continues.
  • Record any area where safe access or egress is reduced by damage, temporary work, storage, construction, maintenance activity, or environmental conditions.
Section 6Electrical systems, panels, lighting, receptacles, cords, and utility-room condition
  • Inspect electrical panels, disconnects, switchgear, distribution boards, and similar equipment for secure covers, visible damage, water exposure, overheating evidence, or unauthorized storage nearby.
  • Confirm required working access around electrical equipment is not obstructed by stored materials, furniture, waste, or temporary equipment.
  • Check receptacles, switches, plugs, extension cords, power strips, visible wiring, junction boxes, and covers for damage, looseness, exposed parts, or other obvious defects.
  • Verify temporary wiring or extension-cord use is controlled by the site's electrical-safety rules and is not being used as an unmanaged permanent facility solution.
  • Inspect normal lighting, emergency lighting, illuminated signs, exterior lights, plant-room lighting, and service-area lighting for failed or damaged units.
  • Escalate electrical burning odor, arcing, damaged insulation, exposed energized parts, water near electrical equipment, repeated breaker trips, or other serious electrical warning signs immediately.
Section 8HVAC, ventilation, plumbing, restrooms, water systems, lifts, and mechanical rooms
  • Inspect HVAC units, air-handling areas, ventilation grilles, filters visible through normal service checks, thermostats, and occupied-area conditions for obvious malfunction or damage.
  • Check mechanical rooms, boiler or plant rooms, pump areas, compressor spaces, and service zones for leaks, unusual noise or vibration, housekeeping issues, blocked access, or stored materials.
  • Inspect plumbing fixtures, pipes, valves, drains, sinks, toilets, washrooms, water heaters, and visible water systems for leaks, damage, blockage, corrosion, or poor drainage.
  • Verify restrooms, wash areas, drinking-water points, janitorial areas, and sanitation facilities are serviceable, clean, supplied, and free from significant defects.
  • Check elevators, lifts, escalators, automatic doors, or similar building transport systems for visible damage, out-of-service status, unusual operation, or overdue service indicators where information is available.
  • Record active leaks, sewage or drainage backup, loss of essential ventilation, mechanical alarms, overheating, unsafe plant-room access, or other urgent utility failures for immediate response.
Section 10Defect prioritization, work orders, preventive maintenance, verification, records, and sign-off
  • Classify each finding by safety, operational, structural, fire, electrical, water-damage, security, accessibility, comfort, cosmetic, or other approved facility category.
  • Prioritize findings using the site's risk and urgency criteria and apply immediate containment or access restriction where an unsafe condition cannot be repaired at once.
  • Create or link work orders, contractor tasks, capital requests, preventive-maintenance actions, cleaning requests, or specialist assessments with named owners and due dates.
  • Verify completed repairs are reinspected when required and evidence confirms the defect is corrected rather than only marked complete in the maintenance system.
  • Trend recurring leaks, lighting failures, trip hazards, HVAC complaints, restroom issues, electrical defects, fire-safety findings, and repeated work orders for preventive action and asset planning.
  • Record final inspection status, critical open risks, restricted areas, work-order references, next inspection date, inspector, facility owner, maintenance owner, and management approval.

Take it with you

Download the printable PDF to inspect facility conditions consistently, record C, PC, NC, or NA findings, capture live defect evidence, and turn building issues into accountable work orders and verified repairs.

Use the complete checklist during your next facility inspection

This internal Facilities & Property template supports routine building and property inspections. Apply current building, fire, electrical, accessibility, lease, maintenance, manufacturer, insurance, and local regulatory requirements as controlling references.
Download PDF Checklist

How to use it

Turn facility inspections into a controlled defect-to-repair workflow

Define the property zones, inspect building and service conditions, control urgent hazards, then assign repairs and verify completion before findings are closed.

01

Define the inspection scope

Select buildings, floors, exterior areas, service rooms, higher-risk assets, prior findings, open work orders, and responsible facility or contractor contacts.

02

Inspect condition and critical access

Walk exterior and interior zones, check surfaces, envelope, electrical and fire access, utilities, housekeeping, storage, and visible equipment condition.

03

Control hazards and assign work

Restrict unsafe areas where needed, photograph defects, classify risk, create work orders or specialist reviews, and assign owners with due dates.

04

Verify repairs and trend recurring issues

Reinspect completed work, confirm evidence, review repeated defects and maintenance backlog, and use trends to improve preventive maintenance and asset planning.

Live interactive demo

See how facility inspections work when they are run in Taqtics

Use the digital workflow to guide property rounds, capture live defect evidence, flag critical building issues, assign work orders, verify repairs, and compare recurring facility problems across sites.

Traceable property evidence

Capture building, floor, zone, asset, defect, live photo, risk, owner, work order, due date, repair evidence, and inspection history together.

Faster repair ownership

Turn leaks, trip hazards, electrical concerns, blocked access, fire-safety defects, HVAC issues, and damage into assigned corrective work.

Comparable facility performance

Track critical findings, recurring defects, aging work orders, repair verification, repeated leaks, lighting failures, and maintenance backlog across properties.

Taqtics
Retail Stock AuditStock Audit Checklist
0 of 6 answered

1 Select the stock-audit area

Dropdown

2 Does the sampled physical quantity match the system quantity after movement cut-off?

Critical score

3 Enter the variance percentage for the sampled item

Measurement

4 Select the evidence reviewed

Multiple choice

5 Add live stock-audit evidence

Live evidence

6 Record the variance, root cause, and required corrective action

Comments

Illustrative website demo. Responses are not stored or submitted.

Why digitize it

A clearer way to manage facility inspections across every property

Taqtics connects scheduled facility rounds, live building evidence, critical findings, work orders, maintenance ownership, verification, asset trends, and reporting across facilities and property portfolios.

Inspect every property consistently

Capture facility, zone, asset, condition, photo, risk, owner, work order, due date, and inspection history together.

Standardize defect and escalation rules

Use consistent C, PC, NC, NA options, critical-finding criteria, evidence requirements, access restrictions, due dates, and follow-up rules.

Close building defects with proof

Assign repairs, cleaning, contractor tasks, specialist inspections, preventive maintenance, or capital work and verify completion with evidence.

Compare facility health across sites

Track critical defects, repeat leaks, trip hazards, lighting failures, blocked access, utility issues, overdue work orders, and repair closure across properties.

Frequently asked questions

Facility inspection checklist FAQs

What should a facility inspection checklist cover?

A broad facility inspection should cover exterior areas, entrances and common spaces, walking surfaces, walls and ceilings, building envelope, electrical condition, fire and emergency access, HVAC and plumbing, restrooms, mechanical rooms, housekeeping, waste, storage, pest evidence, defects, work orders, repair verification, and recurring maintenance issues.

How often should a facility inspection be performed?

Frequency should reflect property type, occupancy, asset condition, lease responsibilities, legal and insurance requirements, previous defects, seasonal risks, and the criticality of building systems. Many organizations combine frequent routine rounds with deeper scheduled inspections.

What does OSHA require for walking-working surfaces in general industry?

Where OSHA general-industry requirements apply, 29 CFR 1910.22 requires walking-working surfaces to be maintained in a clean, orderly, and sanitary condition; kept dry as feasible; inspected regularly and as necessary; and maintained in a safe condition. Apply the exact requirements relevant to the workplace.

What should be checked around emergency exits?

Check that applicable exit routes and discharge areas are usable, unobstructed, appropriately identified, and supported by working emergency safeguards. Under OSHA 1910.37, covered exit routes must remain free and unobstructed. Building and fire-code requirements may add further property-specific criteria.

What electrical items should a facility inspection cover?

A routine facility inspection can identify obvious issues such as damaged covers, water exposure, blocked electrical working access, damaged receptacles or cords, failed lighting, overheating evidence, or exposed parts. Technical electrical work and compliance determinations should be handled by qualified personnel under the applicable electrical requirements.

What should happen after a facility defect is found?

Prioritize the finding by risk and urgency, apply interim controls or restrict access when an unsafe condition cannot be corrected immediately, create the appropriate work order or specialist review, assign ownership and a due date, then verify the completed repair before closure when required.

Digitize every stock audit

Run retail stock audits with live evidence and accountable variance control

Maintain one operational view of count completion, stock accuracy, value variance, shrink risk, open actions, approvals, and recurring inventory-control issues.

Printable PDF | Free Taqtics trial | No credit card required